Filtration Services / Turbine Oil Filtration
Energy • Compressor Stations • Process Plants
Turbine Oil Filtration
Off-line / by-pass filtration and conditioning service aimed at the controlled reduction of particles, water, and process-borne contaminants in turbine oil.
Typical Risks
What do we encounter in the system?
- Fine particle contamination
- Free or emulsified water
- Varnish/oxidation by-products
- Sensitivity in bearings and control elements
- Oil conditioning prior to planned maintenance
OEMLUBE Approach
How do we work?
- By-pass / off-line filtration skids
- Deep filter elements
- Water separation / dehydration according to needs
- Flow rate selection for high-volume tanks
- Verification through pre- and post-oil analysis
Application Principle
The filtration unit is selected according to the system.
Filter micron rating alone is not a sufficient selection criterion. Oil viscosity, temperature, existing pump/valve structure, tank volume, desired circulation time, water load, and target cleanliness value must be evaluated together.
Analysis
Oil and contamination status are determined.
Connection
Suction-return points and safe on-site connections are planned.
Filtration
Oil is cleaned off-line with a controlled flow rate.
Control
The result is confirmed with a final sample and on-site observation.
Information Required for a Quote
Oil type + tank volume + equipment + analysis report
Sharing these four pieces of information accelerates the determination of the correct device/flow rate and operation time.